These single-core medium-voltage cables, available in aluminum (XRUHAKXS/XnRUHAKXS) and copper (XRUHKXS/XnRUHKXS), are designed for environments requiring both longitudinal and radial water sealing. Suitable for installations in buildings, substations, open air, ground, and ducts, the “n” variant offers enhanced flame retardance. Construction includes Class 2 compacted conductors (EN 60228), XLPE insulation with semi-conducting screens, water-swellable tapes, a concentric copper screen, a radial aluminum/plastic laminate barrier, and a weather-resistant PE sheath (black or red).
 
Rated at 3.6/6 kV with a test voltage of 12.5 kV, these cables operate from –60°C to +50°C and withstand short-circuit conditions up to +250°C. Suitable for both indoor and outdoor use at 50 Hz, they support conductor temperatures up to +90°C, meet EN 60332-1-2 fire standards (for “n” type), and allow a bending radius of 15 × D. Available in sizes from 35 mm² to 1000 mm² (Al) and 16 mm² to 50 mm² (Cu).

0.00 KES

XRUHAKXS, XnRUHAKXS, XRUHKXS, XnRUHKXS, HD 620, IEC 60502-2

Additional product information

Power cables rated voltage 3,6/6 kV
XRUHAKXS, XnRUHAKXS, XRUHKXS, XnRUHKXS, HD 620, IEC 60502-2

Application Power cables for medium voltage distribution with XLPE insulation, concentric copper screen, longitudinal and
radial sealing. Suitable for laying in buildings, power stations, in open air, in ground, in cable trays and ducts
where mechanical damages are not expected. "n" - increased flame retardance properties.
Construction 1. Conductor: Aluminum or copper acc. to EN 60228. Class 2 - RMC (stranded, round, compacted);
2. Conductor screen: Semi-conducting XLPE;
3. Insulation: XLPE;
4. Insulation screen: Semi-conducting XLPE;
5. Inner covering: Semiconducting water-swellable tape;
6. Screen: Copper wires and copper tape, applied helically;
7. Inner covering: Semiconducting water-swellable tape;
8. Radial water barrier: Aluminum/plastic laminate tightly attached to outer sheath;
9. Cover: Weather-resistant black color PE. For cables with index "n" - weather-resistant PE (red color).
Parameters 
Exploitation temperature range,°C from -60 to +50
Short-circuit temperature,°C +250
Bending radius 15d
Fire properties EN 60332-1-2 (for cables with index «n>)
Operating conductor temperature,°C max +90
Cabling (inside/outside) inside/outside
Installation temperature,°C min -20
Frequency, Hz 50
Testing voltage, kV 12,5
Rated voltage, kV 3,6/6
Cable sizes 
Al Cu
Number of conductors 1
Minimum conductor size, mm? 35/16
Maximum conductor size, mm2 1000/50 